Press Seal Type CMS60-D

Against pressing water and non-pressing water

Water-tight welded bolts for an optimum of steadiness and corrosion protection

Custom-made for customer-specific requirements

100% gas-, odor- and waterproof

In different material versions available

All products in 48h producible

Proof of pressure-tightness

Figure
 
Item number
 
A | Core drill hole
(mm)
B | Pipes / Cables ø
(mm)
L | Seal
(mm)
Material
 
Pressure-tight
(bar)
Thightning torque
(Nm)
Data sheet
 
CRA21149GGV 50 0-25 60 EPDM / GGV 5 - PDF
CRA21149V4A 50 0-25 60 EPDM / V4A 5 - PDF
CRA21149V2A 50 0-25 60 EPDM / V2A 5 - PDF
CRA21150GGV 60 0-35 60 EPDM / GGV 5 - PDF
CRA21150V4A 60 0-35 60 EPDM / V4A 5 - PDF
CRA21150V2A 60 0-35 60 EPDM / V2A 5 - PDF
CRA21151GGV 70 0-45 60 EPDM / GGV 5 - PDF
CRA21151V4A 70 0-45 60 EPDM / V4A 5 - PDF
CRA21151V2A 70 0-45 60 EPDM / V2A 5 - PDF
CRA21152GGV 80 0-55 60 EPDM / GGV 5 - PDF
CRA21152V4A 80 0-55 60 EPDM / V4A 5 - PDF
CRA21152V2A 80 0-55 60 EPDM / V2A 5 - PDF
CRA21153V2A 100 0-75 60 EPDM / V2A 5 - PDF
CRA21153GGV 100 0-75 60 EPDM / GGV 5 - PDF
CRA21153V4A 100 0-75 60 EPDM / V4A 5 - PDF
CRA21154V2A 125 0-100 60 EPDM / V2A 5 - PDF
CRA21154GGV 125 0-100 60 EPDM / GGV 5 - PDF
CRA21154V4A 125 0-100 60 EPDM / V4A 5 - PDF
CRA21155V2A 150 0-125 60 EPDM / V2A 5 - PDF
CRA21155GGV 150 0-125 60 EPDM / GGV 5 - PDF
CRA21155V4A 150 0-125 60 EPDM / V4A 5 - PDF
CRA21156V2A 200 0-175 60 EPDM / V2A 5 - PDF
CRA21156GGV 200 0-175 60 EPDM / GGV 5 - PDF
CRA21156V4A 200 0-175 60 EPDM / V4A 5 - PDF
CRA21157V2A 250 0-225 60 EPDM / V2A 5 - PDF
CRA21157GGV 250 0-225 60 EPDM / GGV 5 - PDF
CRA21157V4A 250 0-225 60 EPDM / V4A 5 - PDF
CRA21158V2A 300 0-275 60 EPDM / V2A 5 - PDF
CRA21158GGV 300 0-275 60 EPDM / GGV 5 - PDF
CRA21158V4A 300 0-275 60 EPDM / V4A 5 - PDF
CRA21159V2A 350 0-325 60 EPDM / V2A 5 - PDF
CRA21159GGV 350 0-325 60 EPDM / GGV 5 - PDF
CRA21159V4A 350 0-325 60 EPDM / V4A 5 - PDF
CRA21160V2A 400 0-375 60 EPDM / V2A 5 - PDF
CRA21160GGV 400 0-375 60 EPDM / GGV 5 - PDF
CRA21160V4A 400 0-375 60 EPDM / V4A 5 - PDF
CRA21161V2A 450 0-425 60 EPDM / V2A 5 - PDF
CRA21161GGV 450 0-425 60 EPDM / GGV 5 - PDF
CRA21161V4A 450 0-425 60 EPDM / V4A 5 - PDF
CRA21162V2A 500 0-475 60 EPDM / V2A 5 - PDF
CRA21162GGV 500 0-475 60 EPDM / GGV 5 - PDF
CRA21162V4A 500 0-475 60 EPDM / V4A 5 - PDF

Problem

You have pipes/cables which must through a waterproof concrete wall. The feed-through must prevent the ingress of odor, gas or water.


Solution (1/4)

Place the divided Press Seal CMS60-D around the pipe/cable.


Solution (2/4)

Push the Crassus Press Seal Type CMS60-D into the cleaned up wall sleeve (alternative: core drill hole).


Solution (3/4)

Tighten the screws in the following manner, always two diagonally opposite nuts are tightened in succession. Pay attention to the recommended tightening torque.


Solution (4/4)

Done! The feed-through prevents ingress of odor, gas or water.