Press Seal Type CMS60

Against pressing water and non-pressing water

Water-tight welded bolts for an optimum of steadiness and corrosion protection

Custom-made for customer-specific requirements

100% gas-, odor- and waterproof

In different material versions available

All products in 48h producible

Proof of pressure-tightness

Figure
 
Item number
 
A | Core drill hole
(mm)
B | Pipes / Cables ø
(mm)
L | Seal
(mm)
Material
 
Pressure-tight
(bar)
Thightning torque
(Nm)
Data sheet
 
CRA21121GGV 50 0-25 60 EPDM / GGV 5 - PDF
CRA21121V2A 50 0-25 60 EPDM / V2A 5 - PDF
CRA21121V4A 50 0-25 60 EPDM / V4A 5 - PDF
CRA21122GGV 60 0-35 60 EPDM / GGV 5 - PDF
CRA21122V2A 60 0-35 60 EPDM / V2A 5 - PDF
CRA21122V4A 60 0-35 60 EPDM / V4A 5 - PDF
CRA21123GGV 70 0-45 60 EPDM / GGV 5 - PDF
CRA21123V2A 70 0-45 60 EPDM / V2A 5 - PDF
CRA21123V4A 70 0-45 60 EPDM / V4A 5 - PDF
CRA21124GGV 80 0-55 60 EPDM / GGV 5 - PDF
CRA21124V2A 80 0-55 60 EPDM / V2A 5 - PDF
CRA21124V4A 80 0-55 60 EPDM / V4A 5 - PDF
CRA21125GGV 100 0-75 60 EPDM / GGV 5 - PDF
CRA21125V2A 100 0-75 60 EPDM / V2A 5 - PDF
CRA21125V4A 100 0-75 60 EPDM / V4A 5 - PDF
CRA21126GGV 125 0-100 60 EPDM / GGV 5 - PDF
CRA21126V2A 125 0-100 60 EPDM / V2A 5 - PDF
CRA21126V4A 125 0-100 60 EPDM / V4A 5 - PDF
CRA21127GGV 150 0-125 60 EPDM / GGV 5 - PDF
CRA21127V2A 150 0-125 60 EPDM / V2A 5 - PDF
CRA21127V4A 150 0-125 60 EPDM / V4A 5 - PDF
CRA21128GGV 200 0-175 60 EPDM / GGV 5 - PDF
CRA21128V2A 200 0-175 60 EPDM / V2A 5 - PDF
CRA21128V4A 200 0-175 60 EPDM / V4A 5 - PDF
CRA21129GGV 250 0-225 60 EPDM / GGV 5 - PDF
CRA21129V2A 250 0-225 60 EPDM / V2A 5 - PDF
CRA21129V4A 250 0-225 60 EPDM / V4A 5 - PDF
CRA21130GGV 300 0-275 60 EPDM / GGV 5 - PDF
CRA21130V2A 300 0-275 60 EPDM / V2A 5 - PDF
CRA21130V4A 300 0-275 60 EPDM / V4A 5 - PDF
CRA21131GGV 350 0-325 60 EPDM / GGV 5 - PDF
CRA21131V2A 350 0-325 60 EPDM / V2A 5 - PDF
CRA21131V4A 350 0-325 60 EPDM / V4A 5 - PDF
CRA21132GGV 400 0-375 60 EPDM / GGV 5 - PDF
CRA21132V2A 400 0-375 60 EPDM / V2A 5 - PDF
CRA21132V4A 400 0-375 60 EPDM / V4A 5 - PDF
CRA21133GGV 450 0-425 60 EPDM / GGV 5 - PDF
CRA21133V2A 450 0-425 60 EPDM / V2A 5 - PDF
CRA21133V4A 450 0-425 60 EPDM / V4A 5 - PDF
CRA21134GGV 500 0-475 60 EPDM / GGV 5 - PDF
CRA21134V2A 500 0-475 60 EPDM / V2A 5 - PDF
CRA21134V4A 500 0-475 60 EPDM / V4A 5 - PDF

Problem

You have pipes/cables which must through a waterproof concrete wall. The feed-through must prevent the ingress of odor, gas or water.


Solution (1/4)

Use the Crassus Wall Sleeve PVC with the water pressure-tight vulcanized Power-Profile. Note: The needed size of the wall sleeve (alternative: core drill hole) depends on the size and quantity of the pipes/cables.


Solution (2/4)

Push the Crassus Press Seal Type CMS60 into the cleaned up wall sleeve (alternative: core drill hole) and now you can install the pipes/cables.


Solution (3/4)

Tighten the screws in the following manner, always two diagonally opposite nuts are tightened in succession. Pay attention to the recommended tightening torque.


Solution (4/4)

Done! The feed-through prevents ingress of odor, gas or water.