Stainless steel wall sleeve
Producible for every wall thickness
2 end caps as installation aid
Vulcanized Power-Profile
Proofed pressure tightness
Figure   |
Item number |
A | Outside-diameter (mm) |
B | Inside-diameter (mm) |
L | Length (mm) |
Material |
Pressure-tight (bar) |
Thightning torque (Nm) |
Data sheet |
---|---|---|---|---|---|---|---|---|
![]() |
CRA22629 | - | 80 | 200 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22630 | - | 80 | 240 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22631 | - | 80 | 250 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22632 | - | 80 | 300 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22589 | - | 80 | 350 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22590 | - | 80 | 365 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22592 | - | 80 | 450 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22591 | - | 80 | 400 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22593 | - | 80 | 500 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22633 | - | 100 | 200 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22634 | - | 100 | 240 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22635 | - | 100 | 250 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22636 | - | 100 | 300 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22594 | - | 100 | 350 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22595 | - | 100 | 365 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22596 | - | 100 | 400 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22597 | - | 100 | 450 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22598 | - | 100 | 500 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22637 | - | 125 | 200 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22638 | - | 125 | 240 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22639 | - | 125 | 250 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22640 | - | 125 | 300 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22606 | - | 125 | 350 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22607 | - | 125 | 365 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22608 | - | 125 | 400 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22609 | - | 125 | 450 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22610 | - | 125 | 500 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22641 | - | 150 | 200 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22642 | - | 150 | 240 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22643 | - | 150 | 250 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22644 | - | 150 | 300 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22611 | - | 150 | 350 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22612 | - | 150 | 365 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22613 | - | 150 | 400 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22614 | - | 150 | 450 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22615 | - | 150 | 500 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22645 | - | 200 | 200 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22646 | - | 200 | 240 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22647 | - | 200 | 250 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22648 | - | 200 | 300 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22616 | - | 200 | 350 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22617 | - | 200 | 365 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22618 | - | 200 | 400 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22619 | - | 200 | 450 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22685 | - | 200 | 500 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22649 | - | 250 | 200 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22650 | - | 250 | 240 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22651 | - | 250 | 250 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22652 | - | 250 | 300 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22686 | - | 250 | 350 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22687 | - | 250 | 365 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22688 | - | 250 | 400 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22690 | - | 250 | 500 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22653 | - | 300 | 200 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22654 | - | 300 | 240 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22655 | - | 300 | 250 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22656 | - | 300 | 300 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22691 | - | 300 | 350 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22692 | - | 300 | 365 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22693 | - | 300 | 400 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22694 | - | 300 | 450 | V2A / EPDM | 2.5 | - | |
![]() |
CRA22695 | - | 300 | 500 | V2A / EPDM | 2.5 | - |
You have pipes/cables which go through a waterproof concrete wall. The feed-through must prevent the ingress of odor, gas or water.
Use the Crassus Wall Sleeve Stainless Steel with the water pressure-tight Power-Profile.
Place the wall sleeve in the waterproof concrete wall.
Now you have the possibility to create a professional and water pressure-tight feed-through for pipes/cables. Just use a Crassus Press Seal (e.g. Type DS) and place it in the wall sleeve.
Tighten the screws in the following manner, always two diagonally opposite nuts are tightened in succession. Pay attention to the recommended tightening torque.